Sam's is your source for Hatteras and Cabo Yacht parts.

Enter a part description OR part number to search the Hatteras/Cabo parts catalog:

Email Sam's or call 1-800-678-9230 to order parts.

Search results

  1. S

    low freon cut off switch off at 35 psi, on at 70 desired for my old AC cruisair

    I would like to add one, this would go in the suction line. Anyone have a suitable part number that will work?
  2. S

    Old Tecumseh Cruisair compressor turns off after an hour will restart after long time

    I have a decent working knowledge of my old AC unit. It does not seem to be kicking off on high pressure, I have decent water flow, I know what compressor sounds like if the water stops flowing, and it is not like that. The compressor just turns off. It feels warm and you can keep your hand on...
  3. S

    Princess Oven 3 burner model 33 from 1970, need door springs

    Does anyone have a source for springs? Can you get them from Seaward now? These springs hold the door shut. They twist like a lawn mower plastic chute. Left and right hand wound.
  4. S

    Info on Cruisair tecumseh AC Heat Pump compressors

    I called Tecumseh Tech line to get ohm readings for CSR. This is a useful PDF of information on trouble shooting compressors. http://www.tecumseh.com/ta/canada/library/~/media/North%20America/Files/Marketing%20Brochure/North%20America%20Library/Tecumseh%20Service%20Handbook.ashx My compressor...
  5. S

    reverse polarity detection of shore power circuit

    I was wondering if the reverse polarity alarm and light need any fuse protection? My boat simply has it wired to check for voltage between neutral and ground. Also, since your not to have any neutral-ground bonds in the boat, does not the reverse polarity light and alarm in a way make a small...
  6. S

    Cruisair potential relay replacement using APR5 Supco universal adjustable relay

    http://www.supco.com/images/pdfs/Manuals-Instructions/apr5%20-%20supr.pdf This one works. My potential relay failed. The APR5 also fits in the box. I did not like the slotted small screws used for attaching the wires, SO, I used small metal phillips screws from PC computer cases I have saved...
  7. S

    AC compressor going bad? Some measurements I recorded superheat and subcooling

    It worked well in first week of July when we took it out for a couple days. It is a Cruisair 16K btu with fixed orfice metering Compressor does get warm, not too hot to touch. On our earlier trip the compressor was very hot. Since then I insulated the suction line very well. But now sitting in...
  8. S

    supco universal potential relays for a cruisair compressor cube relay

    I came across these here Was wondering if they could be used to replace the cube relay inside the electric box on the condensing unit. http://www.supco.com/images/09%20relay%20&%20hardstarts.pdf What about the reversing valve connections, on my relay wires are on that cube relay. How does the...
  9. S

    modify a propane detector to turn on a blower

    I was looking at the SAFE-T-Alert propane detector which sounds an audible 85 db alarm. model 40-442 http://www.safehomeproducts.com/shp2/product/safe-t-alert-flush-mt-12v-propane-alarm-brown/12v-propane-detectors/160029/160029.aspx manual...
  10. S

    running AC compressor cruisair at lower voltage

    Cruisair compressor if run on shore power I was reading the voltage at 107 volts AC and 57 cycles. When running on gen, the voltage is 121. I also notice it runs little bit quieter on the generator. Does running this at 107 compromise the internal induction motor? Cruisair advertises that if...
  11. S

    cruiseair 16k condensing unit discharge port, the extra shrader port? (lower down)

    If the valve is closed all the way CW, does this port still communicate to the discharge tubing? Can this port be used to vac the system say as installing a charged unit, then open the valves up? What purpose does it serve otherwise? this is the brass covered lower port with a shrader valve...
  12. S

    cruisair 16k condensing valve, how many turns CW to shut the valve?

    I had to file smooth the stem where some gorilla had used vice grip to twist the stem. So I am slightly worried if it turns a lot of CW turns it could eat up the packing. What type packing they use, o rings? I assume all the way CW shuts off the entire port from the compressor-condensing unit.
  13. S

    cruisair 16k btu source price, part numbers, etc for the stem valves condensing unit

    For an older system with rotary knobs. Runs on 120 volts. A typical type F type condensing unit. The 16k has the 1/2 suction tube port Mine in the past someone had chewed up with pliers on the suction port. Still works but who knows how good the seal stem packing still is. If the valves are...
  14. S

    cruisair 16k btu split dual cooler approximate r22 charge in ounces?

    For an older system with rotary knobs. Runs on 120 volts.
Back